- Contact Person : Mr. Jian Zhang
- Company Name : Solcom & HAPN (Shanghai) Electric Co., Ltd.
- Tel : 86-21-51805666
- Fax : 86-21-51805665
- Address : Shanghai,Shanghai,8017 Hutai Road, Baoshan District, Shanghai City. China
- Country/Region : China
- Zip : 201908
HPMV-DN 10kV Medium Voltage Solid State Soft Starter
Medium voltage solid state soft starter:
The HPMV is a third generation, Medium Voltage, digital Medium voltage motor soft starter, designed foruse with standard asynchronous and synchronous motors. This highly sophisticatedsoft starter ensures smooth, step-less acceleration and deceleration, eliminatingcurrent and mechanical shocks on motor and load. The HPMV may be supplied aschassis type or a complete system including Line and/or Bypass Contactors. Addibleoptions are Load Break Switch, Fuses, Motor Protection Relay, etc.
Advantages at a Glance :
Innovative low voltage test mode - full testing with a small L.V motor using standard built in features
Advanced Electronic Potential Transformer utilizing Patent Pending "wireless" fiber-optic firing system
Each starter is tested for Partial Discharge (Korona) ensuring long term reliability
Power factor capacitors can be connected directly to the upstream contactor
Heavy duty design at 50 ambient temperature Reduced inrush current and mechanical shock Third generation microprocessor circuitry Soft, stepless acceleration & deceleration Unique starting & stopping characteristics
Sophisticated motor protection package User friendly, easy setting and operation IP30-standard, higher protection by special order Two optional methods of delivery: Chassis type for self assembly or Complete system RS485 Communication with MODBUS, PROFIBUS protocols (others - upon request)
Wide 45-65Hz Auto-tracking frequency range combining special software with unique hardware arrangement (designed for Marine, Offshore and Generators operating under continuous frequency variation)
Torque and current starting and stopping characteristics.
Pump control software. Starting & Stopping :
Soft start and soft stop
Current limit
Torque & Current Control ramps
Pump Control characteristics
Pulse (kick) start
Tacho/encoder feedback (option)
Dual Adjust - 2 start/stop characteristics for varying loads, two speed motors, etc. Soft starting, Soft Stopping and Final Torque of an HRVS-DN utilizing our infamous "Pump Control Program" Setting & Supervision:
Illuminated LCD with 2 lines, 16 characters each
Selectable languages: English, German, French or Spanish
The LCD displays motor current, fault description and statistical data
Easy setting using six soft-touch keys with default parameters
Eight LEDs for a quick status display:
Control voltage On-Self Test OK
Motor soft starting
Motor running
Motor soft stopping
Motor stopped
Test Mode Activated
Dual Adjust mode
Fault Statistics :
Last Starting Period
Last Start Maximum Current
Total Run Time
Number of Starts
Last Trip
Trip Current
Total Number of Trips
Historical Trip Event Recorder (10 Event conditions) Control Inputs & Outputs:
Control voltage: 110-120, 220-240VAC / 50-60Hz or 110 - 220VDC to be specified
Separate inputs for Start, Stop (Emergency) and Soft Stop
Two programmable External fault inputs - will stop the motor 2 sec. After the contact closes
Aux. Contacts - three C/O relays, 8A, 250V, 2000VA: Immediate Relay - changes position upon start signal, with adjustable On & Off delays. Returns to original position upon Voltage Outage, Fault, Stop signal and Soft stop signal at the end of soft stopping process. It can also be configured as a "Shear-pin Alarm" contact. End of Acceleration Relay - operates upon completion of starting process, with adjustable On delay. Returns to original position upon Voltage outage, Fault, Stop and Soft Stop signals. Fault Relay - can be programmed as: Fault - changes position upon Fault, returns to original position upon Reset. Fault-Fail-Safe - changes position upon control voltage connection, returns upon fault.
Typical Applications:
Fans and centrifuges
Conveyors and monorail systems
Pumps, Compressors and Chillers
Starting large motors from weak power supply(diesel generators, long supply lines, etc.)
Marine & Offshore Applications :
Thrusters
Cargo Pumps (LNG, LPG, etc.)
Water & Ballast pumps
Refrigeration compressors
Hydraulic pumps & power packs
Main Propulsion (Variable Pitch Propellers)
HPMV-DN 10kV Medium Voltage Solid State Soft Starter