Digital Motor Voltage Soft Start
The HPS2DB softatrter is a highly sophisticated and reliable starter designed for use with standard three-phase, three-wire, squirrel cage induction motors. It provides the best method of reducing current and torque during motor starting.
The optional RS 485 Communication with MODBUS protocol enables full control (Start, Stop, Dual Adjust, command, etc.) and supervision. Up to 32 starters can be connected
on a shield twisted pair to a host computer.
Starting & Stopping : Prior to InstallationCheck that Motor's Full Load Ampere is lower than or equal to the starters Full Load Current and that Main and Control voltages are as indicated on the front panel.MountingThe starter must be mounted vertically, allow sufficient space above and below the starter for suitable airflow.It is recommended to mount the starter directly on the rear metal plate for better heat dissipation.Do not mount the starter near heat sources.Protect the starter from dust and corrosive atmospheres.Temp. Range and Heat DissipationThe starter is rated to operate over a temperature range of -10ºC(14ºF) to + 50ºC (122ºF). Relative noncondensed humidity inside the enclosure should not exceed 95%.Starter's heat dissipation is approx. 3 x In (three times the current in watts).Example: For a 100A motor, heat dissipation is approx. 300watts.Internal enclosure heating can be reduced through the use of:a. Additional ventilationb. Employing a by-pass contactor.Short Circuit ProtectionProtect the starter against a short circuit by Thyristor Protection Fuses.
Control Terminals:
Terminals 1-2Control supply110-120Vac or 220-240Vac, 50/60HzTerminal 3GroundTerminal 4Start Signal Input:Input form a N.O contact. To start the motor,connect common terminal (Terminal 6) to Terminal 4 for at least 500mSecs.Terminal 5 Soft Start Signal Input:Input form a N.C contact. To soft stop the motor,disconnect common terminal( Terminal 6 ) to Terminal 5 for at least 500mSecs.Terminal 6Common Terminal,Common for terminals 4,5Terminals 7-8Programmable Signal Relay,Programmable function:Run Relay(Normal Open):Changes its position when starter running(Start/Soft Stop process or Motor running).Over Current Fault Relay(Normal Close):Changes its position on Over Current Fault.Terminals 9-10By-pass relay, changes its position at the end of AccelerationTerminals 11-12Programmable Fault Relay,changes its position on fault, the contact is programmable to function as Normal Open or Normal Close relayOption Module
3) Field Bus Communication Connector:Modbus protocolCode AStandard RS485,Half duplex with Modbus protocol,baud rate 1200,2400,4800,9600 BPSProfibus protocol (Code B)DeviceNet protocol (Code C)RS232C (Code D)Starter control program on-line update
4) Analogue Signal Ouput: Analogue value is related to motor cuurent and operation supplyvoltage.
Digital Motor Voltage Soft Start
Verified Information This information is Verified by Bureau Veritas and validity period is 2012/05/21 --- 2013/05/21 All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >> Production Capacity:Soft Starter, Vector Inverter, Permanent Magnetic Vacuum Circuit Breaker, Permanent Magnetic Vacuum Contactor | 7980 Units per Year | 4030 Units |
South America | USD 142,207 | 0.6 |
Eastern Europe | USD 2,730,314 | 10.5 |
Southeast Asia | USD 13,140 | 0.05 |
Africa | USD 1,076,228 | 4.1 |
Oceania | USD 53,368 | 0.2 |
Mid East | USD 568,250 | 2.2 |
Eastern Asia | USD 27,324 | 0.11 |
Central America | USD 41,597 | 0.16 |
Northern Europe | USD 63,583 | 0.25 |
Southern Europe | USD 45,358 | 0.18 |
South Asia | USD 25,850 | 0.1 |
Domestic Market | USD 21,050,992 | 81.55 |
Bus Bar Machine | Shandong Gaoji, BN303-S-3-8P | 1 | 3.0 | Acceptable |
Bus Bar Machine | DMX-303-SB | 1 | 5.0 | Acceptable |
Bus Bar Bending Machine | Suzhou Tongli, SL-II | 1 | 5.0 | Acceptable |
Oscilloscope | Agilent Technologies & DSO 7054A | 1 | 4.5 | Acceptable |
High Voltage Test Machine | XCJH | 1 | 5.0 | Acceptable |
DC Power | Shanghai Huayi, HY3020 | 1 | 3.0 | Acceptable |
DC Power | Shanghai Huayi, HY3003D-2 | 1 | 3.0 | Acceptable |
Soft Starter Test Board | Solcom & HAPN, HP-1 | 10 | 3.0 | Acceptable |
Low-Voltage Inverter Operation Box | HAPN, OB-HPVFV | 4 | 2.0 | Acceptable |
Power Frequency Withstand Voltage Tester | Nanjing Changsheng, CS2674A | 1 | 8.0 | Acceptable |
RLC Digital Bridge | TH2811C, TH2817B | 2 | 4.0 | Acceptable |
Magnetic Element Selector | Hangzhou Yuanfang, CF-3A | 1 | 3.0 | Acceptable |
Permanent Vacuum Contactor Test Control Board | N/A | 1 | 1.0 | Acceptable |
Certificate for China Compulsory Product Certification | China Quality Certification Centre | 2010010304400493 | Soft Starter, HPS2D-75, HPS2D-90, HPS20-110, HPS20-145; Ith: 75A, 90A, 110A, 145A; Ue: AC400V; Ie:75A, 90A, 110A, 145A; Type: AC-53a; Pole No.:3P | 2010/05/27 --- 2014/09/30 | |
Certificate for China Compulsory Product Certification | China Quality Certification Centre | 2010010304400494 | Soft Starter, HPS2D-175, HPS2D-210, HPS20-250; Ith: 175A, 210A, 250A; Ue: AC400V; Ie:175A, 210A, 250A; Type: AC-53a; Pole No.:3P | 2010/04/23 --- 2014/09/30 | |
Certificate for China Compulsory Product Certification | China Quality Certification Centre | 2010010304400489 | Soft Starter, HPS2DN-175, HPS2DN-210, HPS2DN-250; Ith: 175A, 210A, 250A; Ue: AC400V; Ie:175A, 210A, 250A; Type: AC-53a; Pole No.:3P | 2010/04/08 --- 2014/09/30 | |
Certificate for China Compulsory Product Certification | China Quality Certification Centre | 2010010304400496 | Soft Starter, HPS2DN-18, HPS2DN-30, HPS2DN-40, HPS2DN-60, HPS2DN-75, HPS2DN-90, HPS2DN-110, HPS2DN-145; Ith: 18A, 30A, 45A, 60A, 75A, 90A, 110A, 145A; Ue: AC400V; Ie: 18A, 30A, 45A, 60A, 75A, 90A, 110A, 145A; Type: AC-53a; Pole No.:3P | 2010/04/08 --- 2014/09/30 | |
Certificate for China Compulsory Product Certification | China Quality Certification Centre | 2010010304400490 | Soft Starter, HPS2DN-300, HPS2DN-370, HPS2DN-470, HPS2DN-570, HPS2DN-720, HPS2DN-840; Ith: 300A, 370A, 470A, 570A, 720A, 840A; Ue: AC400V; Ie: 300A, 370A, 470A, 570A, 720A, 840A; Type: AC-53a; Pole No.:3P | 2010/04/08 --- 2014/09/30 | |
Certificate for China Compulsory Product Certification | China Quality Certification Centre | 2010010304400495 | Soft Starter, HPS2D-300, HPS2D-370, HPS2D-470, HPS2D-570, HPS2D-720, HPS2D-840; Ith: 300A, 370A, 470A, 570A, 720A, 840A; Ue: AC400V; Ie: 300A, 370A, 470A, 570A, 720A, 840A; Type: AC-53a; Pole No.:3P | 2010/04/08 --- 2014/09/30 | |
CE Certification of Conformity | Belcome Technology Service | bel-cn-071015-31 | Inverter, HPI 5000(0.75KW-350KW) | 2007/10/18 --- 2049/12/31 |
CCC Test Report | Shanghai Institute of Electric Equipment inspection | Soft Starter, HPS2D-300, HPS2DN-370, HPS2DN-470, HPS2DN-570, HPS2DN-720, HPS2DN-840 | 2009/11/23 | |
CCC Test Report | Shanghai Institute of Electric Equipment inspection | Soft Starter, HPS2DN-18, HPS2DN-30, HPS2DN-45, HPS2DN-60, HPS2DN-75, HPS2DN-90, HPS2DN-110, HPS2DN-145 | 2009/11/23 | |
CCC Test Report | Shanghai Institute of Electric Equipment inspection | Soft Starter, HPS2DN-175, HPS2DN-210, HPS2DN-250, | 2009/11/23 | |
CCC Test Report | Shanghai Institute of Electric Equipment inspection | Soft Starter, HPS2DN-300, HPS2DN-370, HPS2DN-470, HPS2DN-570, HPS2DN-720, HPS2DN-840. | 2009/11/23 | |
CCC Test Report | Shanghai Institute of Electric Equipment inspection | Soft Starter, HPS2D-175, HPS2D-210, HPS2D-250 | 2009/11/23 |